Search results for " precession"
showing 10 items of 43 documents
Systematic and statistical uncertainties of the hilbert-transform based high-precision FID frequency extraction method.
2021
Abstract Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is one of the methods that have been used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described, and it is briefly compared with other commonly used frequency extraction methods. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytical…
Accretion in strong field gravity with eXTP
2019
In this paper we describe the potential of the enhanced X-ray Timing and Polarimetry (eXTP) mission for studies related to accretion flows in the strong field gravity regime around both stellar-mass and supermassive black-holes. eXTP has the unique capability of using advanced 'spectral-timing-polarimetry' techniques to analyze the rapid variations with three orthogonal diagnostics of the flow and its geometry, yielding unprecedented insight into the inner accreting regions, the effects of strong field gravity on the material within them and the powerful outflows which are driven by the accretion process.
Kardiale MRT : Änderungen der normalisierten myokardialen Gadolinium-Anreicherung über die Zeit nach Kontrastmittelinjektion in Patienten mit akuter …
2011
PURPOSE An increased normalized gadolinium accumulation (NGA) in the myocardium during early washout has been used for the diagnosis of acute myocarditis (AM). Due to the fact that the pharmacokinetics of contrast agents are complex, time-related changes in NGA after contrast injection are likely. Because knowledge about time-related changes of NGA may improve the diagnostic accuracy of MR, our study aimed to estimate the time course of NGA after contrast injection in patients as well as in healthy volunteers. MATERIALS AND METHODS An ECG-triggered inversion recovery SSFP sequence with incrementally increasing inversion times was repetitively acquired over the 15 minutes after injection of …
Quantitative criteria for the diagnosis of the congenital absence of pericardium by cardiac magnetic resonance
2015
Congenital absence of the left ventricular pericardium (LCAP) is a rare and poorly known cardiac malformation. Cardiac Magnetic Resonance (CMR) is generally used for the diagnosis of LCAP because of its high soft tissue contrast, multiplanarity and cine capability, but the diagnosis is usually made by only qualitative criteria. The aim of the present study was to establish quantitative criteria for the accurate diagnosis of LCAP on CMR.We enrolled nine consecutive patients affected by LCAP (mean age 26±8years, 7 males), 13 healthy controls, 13 patients with dilated cardiomyopathy (DCM), 12 patients with hypertrophic cardiomyopathy (HCM) and 13 patients with right ventricular overload (RVO).…
Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences
2005
Purpose To compare steady-state free precession (SSFP) sequence protocols with different acquisition times (TA) and temporal resolutions (tRes) due to the implementation of a view sharing technique called shared phases for the assessment of left ventricular (LV) function by breath-hold cine magnetic resonance (MR) imaging. Materials and Methods End-diastolic and end-systolic volumes (EDV, ESV) were measured in contiguous short-axis slices with a thickness of 8 mm acquired in 10 healthy male volunteers. The following true fast imaging with steady-state precession (TrueFISP) sequence protocols were compared: protocol A) internal standard of reference, segmented: tRes 34.5 msec, TA 18 beats pe…
A Precessing Ferromagnetic Needle Magnetometer
2016
A ferromagnetic needle is predicted to precess about the magnetic field axis at a Larmor frequency $\Omega$ under conditions where its intrinsic spin dominates over its rotational angular momentum, $N\hbar \gg I\Omega$ ($I$ is the moment of inertia of the needle about the precession axis and $N$ is the number of polarized spins in the needle). In this regime the needle behaves as a gyroscope with spin $N\hbar$ maintained along the easy axis of the needle by the crystalline and shape anisotropy. A precessing ferromagnetic needle is a correlated system of $N$ spins which can be used to measure magnetic fields for long times. In principle, by taking advantage of rapid averaging of quantum unce…
Ferromagnetic gyroscopes for tests of fundamental physics
2020
A ferromagnetic gyroscope (FG) is a ferromagnet whose angular momentum is dominated by electron spin polarization and that will precess under the action of an external torque, such as that due to a magnetic field. Here we model and analyze FG dynamics and sensitivity, focusing on practical schemes for experimental realization. In the case of a freely floating FG, we model the transition from dynamics dominated by libration in relatively high externally applied magnetic fields, to those dominated by precession at relatively low applied fields. Measurement of the libration frequency enables in situ measurement of the magnetic field and a technique to reduce the field below the threshold for w…
Experimental benchmarking of quantum control in zero-field nuclear magnetic resonance
2017
Zero-field nuclear magnetic resonance (NMR) provides complementary analysis modalities to those of high-field NMR and allows for ultra-high-resolution spectroscopy and measurement of untruncated spin-spin interactions. Unlike for the high-field case, however, universal quantum control -- the ability to perform arbitrary unitary operations -- has not been experimentally demonstrated in zero-field NMR. This is because the Larmor frequency for all spins is identically zero at zero field, making it challenging to individually address different spin species. We realize a composite-pulse technique for arbitrary independent rotations of $^1$H and $^{13}$C spins in a two-spin system. Quantum-inform…
Polarization-driven spin precession of mesospheric sodium atoms
2018
We report experimental results on the first on-sky observation of atomic spin precession of mesospheric sodium driven by polarization modulation of a continuous-wave laser. The magnetic resonance was remotely detected from the ground by observing the enhancement of induced fluorescence when the driving frequency approached the precession frequency of sodium in the mesosphere, between 85 km and 100 km altitude. The experiment was performed at La Palma, and the uncertainty in the measured Larmor frequency ($\approx$260 kHz) corresponded to an error in the geomagnetic field of 0.4 mG. The results are consistent with geomagnetic field models and with the theory of light-atom interaction in the …
The structure of charoite, (K,Sr,Ba,Mn)(15-16)(Ca,Na)(32)[(Si-70(O,OH)(180))](OH,F)(4.0)center dot nH(2)O, solved by conventional and automated elect…
2010
AbstractCharoite, ideally (K,Sr,Ba,Mn)15–16(Ca,Na)32[(Si70(O,OH)180)](OH,F)4.0·nH2O, a rare mineral from the Murun massif in Yakutiya, Russia, was studied using high-resolution transmission electron microscopy, selected-area electron diffraction, X-ray spectroscopy, precession electron diffraction and the newly developed technique of automated electron-diffraction tomography. The structure of charoite (a= 31.96(6) Å,b= 19.64(4) Å,c= 7.09(1) Å, β = 90.0(1)°,V= 4450(24) Å3, space groupP21/m) was solvedab initioby direct methods from 2878 unique observed reflections and refined toR1/wR2= 0.17/0.21. The structure can be visualized as being composed of three different dreier silicate chains: a d…